Lion Solar Solutions

Solar, Battery and EV Charging Modeled Together: A Verified 12.61 kWp Residential Case Study

October 22, 2026

Solar, Battery and EV Charging Modeled Together: A Verified 12.61 kWp Residential Case Study

The Engineering Challenge

A residential property in the Cologne region of Germany required a rooftop solar system that had to do more than offset household electricity use. The brief included a dual-pitch roof with modules split almost evenly between a southeast and a northwest orientation, a 10 kWh lithium iron phosphate battery, and an electric vehicle with an 11 kW DC CCS home charger. The challenge was not module placement. It was accurately predicting how three time-dependent loads, household consumption, battery charge and discharge cycles, and EV charging demand, would interact with a generation profile that is inherently split between morning and evening peaks because of the opposing roof orientations.

We model systems like this one in our PV*SOL solar design service, with the project file and the simulation report the installer uses in the offer.

In our projects we consistently see that this type of mixed-orientation, multi-asset system is where simplified sizing tools fall short. A system sized only on annual kWh generation versus annual kWh consumption can look balanced on paper while performing poorly in practice, because the timing of generation, storage dispatch and vehicle charging demand determines the real-world outcome far more than the annual totals do.

Solar, Battery and EV Charging Modeled Together: A Verified 12.61 kWp Residential Case Study 1

The Approach and Methodology

We modeled the full system in PV*SOL using hourly climate data from PVGIS-SARAH3 for Neunkirchen-Seelscheid. The array consists of 26 Aiko AIKO-A485-MCE54Db modules, 13 facing southeast at 124 degrees and 13 facing northwest at 304 degrees, both at a 10 degree pitch, for a combined 12.61 kWp. This was paired with a Sungrow SH12T inverter and a Sungrow SBH100 battery system rated at 10 kWh usable capacity with a 6 kW battery inverter operating through a DC intermediate circuit coupling.

The household load profile of 3,000 kWh per year was modeled against a standard load profile shape with a 16.2 kW peak. The electric vehicle, a 21.6 kWh usable battery capacity vehicle with 12.9 kWh per 100 km consumption, was modeled with a weekly target range of 288 km and an annual mileage of 15,017 km, charged through an 11 kW DC CCS connection. Critically, we did not model the EV or the battery as independent blocks. We simulated them as a single dispatch system against the hourly generation profile, which is the only way to capture how a dual-orientation roof’s broader daily generation window interacts with both storage assets competing for the same solar surplus.

Solar, Battery and EV Charging Modeled Together: A Verified 12.61 kWp Residential Case Study 2

The Results

The simulation returned a specific annual yield of 932.15 kWh per kWp with a performance ratio of 85.07 percent, including a 2.5 percent shading loss. Of the 11,610 kWh of annual PV generation delivered to the AC side with battery interaction included, 2,424 kWh was consumed directly, 1,534 kWh charged the EV, and 7,653 kWh was exported to the grid.

On the demand side, the combined household and EV load reached 5,359 kWh per year. Of this, 3,958 kWh was covered by PV generation and battery storage combined, leaving only 1,401 kWh drawn from the grid. That yields a solar coverage ratio, what PV*SOL terms the autarky rate, of 73.8 percent. For the vehicle specifically, of the 15,017 km driven annually, 9,789 km were powered entirely by solar energy, meaning roughly two-thirds of all driving on this property is now solar-sourced rather than grid-sourced. The battery cycled at 4.5 percent annual throughput relative to its capacity with a projected service life beyond 20 years, indicating the system is sized conservatively rather than being pushed to its thermal or cycle limits.

Solar, Battery and EV Charging Modeled Together: A Verified 12.61 kWp Residential Case Study 3

Why Lion Solar is Better Than Reonic and Solarmonkey for Complex PV Projects

Quick-proposal platforms such as Reonic or Solarmonkey are built for fast 2D sales quotes on straightforward rooftop systems. They are effective at producing a fast budgetary number for a single-orientation roof with no storage or EV load. They are not built to run hourly dispatch simulations across multiple interacting assets, which is precisely the limitation that matters on a project like this one.

A dual-orientation roof with a battery and an EV charger has three variables that only resolve correctly in an hourly, full-year simulation: when the southeast and northwest arrays each produce their peak output, when the battery should charge versus discharge to maximize self-consumption rather than simply cycling, and when the EV charger should draw from solar surplus versus grid power to hit its weekly range target. A 2D proposal tool working from annual totals cannot model this interaction. It can tell a customer that their annual generation exceeds their annual consumption. It cannot tell them that their EV will run on solar power 65 percent of the time, or that their realistic autarky rate is 73.8 percent rather than some generic percentage pulled from a sizing table. For projects like this, engineering-grade hourly simulation is where Lion Solar is simply better than Reonic or Solarmonkey.

Solar, Battery and EV Charging Modeled Together: A Verified 12.61 kWp Residential Case Study 4

What This Means for EPCs and Investors

For EPC contractors selling multi-asset residential systems, this case demonstrates why PV*SOL design and solar simulation services are not an optional add-on for projects involving battery storage and EV charging. The commercial pitch to a homeowner, how much of my driving will be solar-powered, how much will I still pay the grid, is only answerable with the kind of hourly dispatch modeling we ran here. Underselling the autarky rate because of a generic calculation risks losing the sale. Overselling it because of an optimistic annual-balance calculation risks a customer complaint once the first electricity bill of a cloudy month arrives.

For investors and homeowners financing these systems, the distinction between annual energy balance and hourly dispatch-verified autarky is the difference between a marketing number and a number you can plan a household budget around. As we modeled in this project, pairing dual-orientation generation with a correctly sized battery and EV charging profile produces a system where almost three-quarters of total household and vehicle energy needs are met from the sun, a figure that stands up to year-round, hour-by-hour scrutiny rather than a seasonal average.