PV design services give you a simulation with yield and losses, a module layout, string plan and single line diagram, and, depending on the job, the structural report for the mounting system. The quickest way to judge quality is to look at real results, and three of our projects show what the simulation answers before a single module goes on the roof.

Live demo: Get a personal 30-minute live walkthrough of LSS, tailored to your business. Book a live demo

What do PV design services include?

Our design work comes in three parts. The first is the simulation: our PV*SOL planning service covers the 3D layout, shading, string planning, the yield forecast and a report you can show a client. The second is the drawings, which we produce in AutoCAD solar planning as DWG, DXF and PDF. The third, where the job calls for it, is the structural report for the mounting system under substructure planning.

Our sample report for a 7.44 kWp system in Germany shows the scale. It has 34 pages, four of them drawings, and you get the PV*SOL project file with it, plus a PDF report that we can put in your company’s design. What the simulation finds on a real roof is easier to see in three projects, all three in Germany.

One roof, two orientations: 15.64 kWp in Herford

The roof split into two planes, northeast at 59 degrees azimuth and southwest at 239 degrees, both pitched at 35 degrees. Thirty-four modules, 11 on one plane and 23 on the other, fed a three-phase 15 kW inverter through three MPP trackers, wired as 1×11, 1×11 and 1×12, with a 9.6 kWh battery on top.

The wiring was not the interesting part. The shading, simulated module by module, was. Most modules lost under 0.3 percent of annual irradiance. One group on the southwest plane lost 5.7 percent because of a vent pipe next to it. A single shading factor across the whole 67.9 m² array would have hidden that group. The result was 837.57 kWh per kWp, a performance ratio of 88.20 percent and 3.8 percent shading loss overall. The dual orientation roof case study sets out the whole loss chain.

Five roof planes, three MPP trackers: 27.9 kWp in Baden-Württemberg

This building spread its modules over five planes, with orientations from 72 to 252 degrees and pitches from 28 to 45 degrees. How the strings were grouped was the real design decision. The two east planes, 13 and 12 modules, went to one tracker. The west plane, as two strings of 11, went to the second. The two south planes, 6, 3 and 6 modules, went to the third. Strings with different irradiance profiles on one tracker would have caused mismatch losses.

The simulation returned 741.41 kWh per kWp and a performance ratio of 81.14 percent. The biggest loss item was not shading at 3.6 percent but orientation and tilt at 22.45 percent. A client conversation goes better with that number than with a rule of thumb, because it is known before the quote goes out. The five roof plane case study has the details.

South-facing frames because of a forest: 148 kWp on an industrial roof

An industrial facility in Germany had tall trees on its east and west sides. The PV*SOL simulation showed that a standard east-west layout would have brought long tree shadows and mismatch losses in the morning and evening. We designed a mounting structure that faces the modules due south and grouped the strings so that any remaining partial shading does not hit the whole array. The outcome was 148.33 kWp producing 159,071 kWh a year, roughly 1,070 kWh per kWp, with near zero shading loss. The 148 kWp forest case study describes the approach.

What to take from the three projects

Each project turned on a question a single derating factor cannot answer: where exactly does the yield go? A design provider who gives you only an annual total does not answer it. Ask for the loss diagram and for shading at module level. You can judge a provider on that before you hire. The other checks we would apply to any provider are in how to choose a solar design provider.

How a design job runs with us

In the Lion Solar Portal you pick the documents you need on one screen: the PV*SOL project and report, string plan, single line diagram, substructure plan and, if you want it, the structural report for K2, Schletter or SL Rack. Our engineers produce them and upload them to the same project, and every revision is versioned. Revisions are included.

Author: Heval Arcan, Lion Solar Solutions. As of October 2026.