Drone Solar Site Survey: What a 3D Roof Model Covers
October 30, 2026

A drone solar site survey gives you the roof side of a site survey: the dimensions for the layout, the position of chimneys, dormers and vents, and a model of the building that the shading calculation can use. It does not see the consumer unit, the rafters or the condition of the tiles, so the electrical and structural parts of the survey stay with someone on site. We checked the dimensional accuracy against a tape and laser on three buildings.
Your first 3D model from drone photos is free. Every company gets a one-off model credit to test the whole process on a real roof. Create your first 3D model for free
The Lion Solar Portal builds the model from photos you take with your own drone. We do not fly for you. Measuring and sharing work in the browser, and if you want the design done as well, it sits in the same project as the 3D roof model from drone photos.
What does a drone solar site survey cover, and what does it miss?
A solar site survey collects four things: the roof geometry, the obstructions and shading, the roof structure, and the electrical side, which means where the consumer unit and meter are and where an inverter or battery can go. The drone covers the first two. From a ladder or scaffold you measure what you can reach. A model on your screen lets you measure again when a question comes up later, without another visit to the roof.
In the portal viewer you measure distances, heights, areas and corners. The roof faces are detected automatically and marked. That is what changes most in a solar roof survey with a drone: the dimensions become one file that everyone on the project works from.
How accurate is a drone solar site survey?
We tested it in October 2026 on three buildings: a detached house, a warehouse and a villa. We measured each distance on site with a laser distance meter or a steel tape, and measured the same distance again in the 3D model. The photos came from a DJI Lito X1. Six of the twelve distances:
| Building | Distance | On site | In the model | Difference |
|---|---|---|---|---|
| Detached house | Eaves | 12.45 m | 12.43 m | 2 cm |
| Detached house | Facade width | 15.20 m | 15.23 m | 3 cm |
| Warehouse | Eaves | 18.50 m | 18.52 m | 2 cm |
| Warehouse | Facade width | 22.00 m | 21.96 m | 4 cm |
| Villa | Garage door | 2.75 m | 2.77 m | 2 cm |
| Villa | Roof window | 0.78 m | 0.77 m | 1 cm |
Across all twelve distances the difference was between 1 and 4 cm, the largest on the 22 m warehouse facade. A portrait module is around 1.1 m wide, and the gap between two modules is usually a centimetre or two, depending on the clamp. Four centimetres over 22 m will rarely change the number of modules in a row. It matters when the last module only just fits or only just does not. In that case it is worth re-measuring the distance with a laser before you fix the layout.
The test has limits. We compared distances, not pitch angles, on three buildings with one drone, and it is not a certification.
What does the model show about obstructions and shading?
Chimneys, parapet walls and nearby trees appear in the model and can be measured, as long as they are visible in the photos. You read the distance and height in the viewer and enter them into the design.
One of our PV*SOL simulations shows why the position and height of an obstruction belong in the design. On a roof in Herford, Germany, most modules lost less than 0.3 percent of annual irradiance to shading. One group lost 5.7 percent because of a roof vent pipe next to it. The example says nothing about drones. It shows that a single pipe costs a module group noticeably, and that one blanket shading factor would miss it. The figures are in the dual orientation roof case study, and the method in our article on PV*SOL shading analysis.
What does a drone survey not show?
A flight around the building shows the outside. Where the inverter will hang, what the consumer unit looks like and how cables run through the house cannot be seen on any photo. The same goes for the rafters under the covering and the condition of the roof under the tiles.
This also applies to the structural side. We supply the structural report for the mounting system, for example for K2, Schletter or SL Rack, with the snow and wind loads for the site. It does not show that the roof structure can carry the load. That question belongs to a structural engineer, who needs information about the construction that a drone model cannot give. Our page on structural calculations for solar PV mounting systems explains what the calculation includes.
How does the 3D model get into the solar design?
There are two ways. In the first you download the model and design yourself. PV*SOL reads OBJ files, and our guide to the PV*SOL 3D import of a drone model shows what to watch for. DXF and DWG are available for CAD work, and the downloads are free.
In the second you have us do the design. In the portal you tick what you need on one screen. Our engineers produce the PV*SOL planning service with layout, shading and string plan, and upload the results to the same project that holds the model. Every revision is versioned. Live demo:
What do you need for the first flight?
You need a drone with GPS that saves JPG or DNG photos, at least 40 photos from one flight around the building, and no photos sent through a messenger app, because they lose their location data. There is no requirement on drone brand or model, and you do not need RTK. The portal checks the photos before the model is calculated, and if the calculation fails the credit is returned. The legal side of the flight is covered in our article on UK drone rules for solar roof surveys.
Author: Heval Arcan, Lion Solar Solutions. As of October 2026.