Case Study: Engineering a 61.38 kWp Dual Orientation Commercial Rooftop Array to 0.6 Percent Shading Loss
October 29, 2026

The Engineering Challenge
A 61.38 kWp commercial rooftop array on a flat industrial style roof in Leipzig, Germany, presented a layout problem that is common on large flat roofs but frequently underestimated. The available roof area required splitting the 132 modules across two opposing orientations, one field facing northwest at 297 degrees and the other facing southeast at 117 degrees, both tilted at a shallow 10 degrees on ballasted east west racking. Opposing orientations on a shared roof introduce two compounding risks. The first is self shading between rows and between the two fields as the sun moves through the day. The second is electrical mismatch, since modules facing away from peak sun at a given hour produce meaningfully less current than modules facing toward it, and if they are wired into the same MPP tracker that mismatch becomes a yield loss rather than a design detail. For EPCs bidding this kind of flat roof commercial project, getting the shading and string design wrong by even a small margin compounds across 132 modules and a 20 plus year operating life.

Our Approach and Methodology
In our PV planning and solar simulation work for EPCs and developers, this is exactly the category of project where a full 3D model earns its cost before a single module is ordered. We modeled the complete roof geometry, parapet heights, and rooftop obstructions in PV*SOL, then simulated the two module fields, Reichpietschstraße 2-Roof Area Southeast at 297 degrees and the second field at 117 degrees, as physically distinct surfaces rather than a single averaged array. This distinction matters because it lets the simulation calculate module specific irradiance and shading independently for each orientation before anything is combined electrically.

On the inverter side, we designed the stringing around a single SMA Sunny Tripower X 60 configured with five separate MPP trackers. The two large fields of 66 modules each were broken into strings of 1×14, 1×13, 3×13, 1×13, 1×14, and 3×13, deliberately separating the Southeast and Northwest facing module groups onto independent MPP inputs. This string architecture lets each orientation track its own maximum power point rather than being averaged with its electrical opposite, which is the detail that prevents orientation mismatch losses in a dual aspect flat roof layout. We sized the inverter to a 103.3 percent DC to AC ratio, intentionally oversizing the DC side to capture more low angle morning and evening production from the shallow 10 degree tilt without triggering meaningful clipping losses.
We then ran the full annual simulation against Leipzig climate data sourced from PVGIS-SARAH3, verifying hourly irradiance, temperature derating, and module level shading loss across all 132 modules in both fields.

Results With Verified Numbers
The simulation confirmed a shading loss of just 0.6 percent, a figure that reflects the precision of the 3D rooftop geometry rather than a generic assumption. Despite the shallow 10 degree tilt and the dual opposing orientation layout, which naturally suppresses specific yield compared to a south facing optimal tilt system, the array still reached a specific annual yield of 855.45 kWh per kWp and a performance ratio of 81.13 percent. Annual grid export was calculated at 52,577 kWh, with 52,275 kWh projected in the first year once module degradation is accounted for. The system is projected to avoid 24,679 kg of CO2 emissions per year. The detailed energy balance shows the STC conversion step accounting for the largest single loss category at 76.71 percent, which is expected physics, while reflection losses from the module surface were measured at 6.86 percent, a figure directly tied to the shallow tilt angle and worth flagging to any EPC bidding a similarly low pitch flat roof design. Mismatch losses from stringing and shading combined came in at only 0.24 percent, confirming that the five way MPP separation did its job of isolating the two orientations from each other electrically.

Why Lion Solar is Better Than Reonic and Solarmonkey for Complex PV Projects
Quick proposal tools built for residential and small commercial sales cycles, the category that includes platforms like Reonic or Solarmonkey, are built to generate a fast 2D quote with a generic shading or production estimate layered on top. That workflow is adequate for a single orientation pitched roof with a handful of modules and minimal obstruction. It is not built to resolve a dual orientation flat roof array where two module fields face in nearly opposite directions and feed a shared inverter. A 2D or quick estimation tool has no mechanism to model orientation specific irradiance for each roof field independently, no way to simulate how a five tracker MPP configuration isolates mismatch between opposing module groups, and no bankable hourly simulation output that a lender or asset owner can audit. For projects like this, engineering grade 3D simulation with independent module field modeling and detailed string level loss accounting is where Lion Solar is simply better than Reonic or Solarmonkey. The 0.6 percent shading result and the 0.24 percent mismatch figure on this project did not come from a generic estimate, they came from resolving 132 modules across two orientations and five MPP inputs individually.
What This Means for EPCs and Investors
For EPC contractors quoting flat roof commercial projects with limited or mixed orientation options, this case demonstrates that a dual aspect layout does not have to come with a shading or mismatch penalty if the string architecture is designed around the geometry rather than around convenience. In our projects we consistently see that the cost of running a full 3D simulation and a multi MPP string design upfront is small compared to the yield that is protected by avoiding orientation mismatch across a 20 year asset life. For investors and asset owners, the verified 0.6 percent shading loss, 81.13 percent performance ratio, and the clean separation of loss categories in the energy balance provide the kind of granular, auditable evidence that supports confident underwriting of a commercial rooftop asset, independent of the installation contractor and free of any conflict of interest in the reported numbers.